Skip to content

Troubleshooting audio

Confirming audio flow

The RX channel level meters in RimuDAX respond to signals received on the corresponding slice in RimuSDR. If signals are present on the slice, the meter must move.

A silent meter

A silent meter when signals are present usually has one of two causes:

  1. The DAX button is not enabled on the slice in RimuSDR.
  2. The wrong DAX channel number is selected on the slice.

Check each in turn.

Checklist

RimuSDR connected first
RimuSDR must be connected, with the DAX button active on the slice, before RimuDAX starts. See Connecting RimuDAX.
Channel numbers match
Slice DAX channel 1 maps to RX1, channel 2 to RX2, and so on. See Audio channels.
Same station
RimuDAX must be connected to the same station as RimuSDR.
TX enabled before RX
Enable the TX channel before you enable any RX channel.
Correct device selected
Your software must use rimu.dax.rx1 as its input and rimu.dax.tx as its output. See PulseAudio device names.

If levels are still wrong, open pavucontrol while RimuDAX is running and confirm the streams are connected to the rimu. devices.